2 pieces
30KVA UPS Single Utility Feed C-Tier without Maintenance Bypass Delixi Total Capacity 63A Standard Distribution
30KVA Wall-mount Single Utility Power , 9 Dual Circuit Solution , Backup Half h
- Tag 1
- 2 pieces
- Tag 2
- 63A
- Tag 3
- Class C
Solutions

2 pieces
30KVA Wall-mount Single Utility Power , 9 Dual Circuit Solution , Backup Half h

3 pieces
30KVA UPS Single Utility Feed C-Tier with Maintenance Bypass Delixi Standard Distribution 5.5KW Cooling Only Air Conditioner Total Capacity 125A Backup 1 h

6 pieces
3-Phase In / 3-Phase Out 10KVA UPS Single Utility Feed C-Tier with Maintenance Bypass Delixi Total Capacity 100A Standard Distribution with 12.5kW Air Conditioner Backup 1 h

16 pieces
Total Capacity 63A Delixi Single Utility Feed Input with 3-Phase In / 3-Phase Out 20KVA UPS Backup 1 h

12 pieces
Total Capacity 80A Single Utility Feed Feed Delixi with 3-Phase In / 3-Phase Out 20KVA UPS

6 pieces
Total Capacity 100A Single Utility Feed Feed Delixi with 10KVA UPS

6 pieces
Total Capacity 63A Single Utility Feed Feed Delixi with 3-Phase In / 1-Phase Out 10KVA UPS

4 pieces
10KUPS Power 7.5KW Air Conditioner 11-Circuit with Maintenance Bypass Backup 1 h

16 pieces
The total capacity is 200A single-channel commercial power input, and the computer room is equipped with 80KVA UPS power supply with three inputs and three outlets to provide uninterruptible power supply for 16 cabinets. After the commercial power is cut off, the supply can be delayed for 30 minutes. Also equipped with 35KW precision air conditioning and fresh air system.

3 pieces
The total capacity is 125A, and the power distribution is in the form of power distribution units to save space. Single-channel Utility Power power input, equipped with three-in and three-out 30KVA UPS to provide uninterruptible power supply for 3 cabinets, entrance guard, monitoring, splicing screen, etc. After the Utility Power power is cut off, the supply can be delayed for 30 minutes. Also equipped with 12.5KW precision air conditioning.

20
Total capacity 125A, two-way Utility Power access, ATS mutual investment. Equipped with three-in and three-out 20KVA UPS, it provides uninterruptible power supply for 20 cabinets, which can be delayed for 1 hour after power failure to ensure server data security. Another 12.5KW single cooling precision air conditioning.

4 pieces
Total capacity 125A single-channel Utility Power access with three-in single-out 20KVA UPS to supply power to 4 cabinets, entrance guard and operating desk lamps. Also equipped with 7.5KW single cooling precision air conditioning.